Take Control of Your Power: Resolving Generac Generator Tripping Problems

Home | Take Control of Your Power: Resolving Generac Generator Tripping Problems

Understanding Generac Generators

Generac generators are a reliable source of backup power for your home, ensuring that you remain comfortable and your appliances stay on even during an outage. Understanding the basics of how your Generac generator operates and familiarizing yourself with common error codes can help you take control when issues arise.

Basics of Generac Generators

Generac generators are designed to provide a seamless transition to backup power in case of an electrical failure. They are typically powered by natural gas or propane and can be permanently installed as standby units. When your main power supply is interrupted, the generator detects the problem and automatically begins to supply power.

The unit is equipped with a control panel that displays status messages and error codes. It’s important to regularly check and maintain your generator, ensuring that it’s ready to function when needed. Regular maintenance includes checking oil levels, ensuring the battery is charged, and keeping the unit clean and free from debris.

If you experience issues such as your Generac generator keeps tripping, you may need to perform a reset. Detailed generac generator reset instructions can be found in the accompanying manual or on our how to reset generac generator page.

Common Error Codes

Generac generators are equipped with self-diagnostic capabilities that display error codes on the control panel when there is an issue with the system. These codes indicate specific problems that can guide you in troubleshooting and fixing the unit. Below is a table summarizing some of the most common error codes you might encounter:

Error Code Description
1100 Overcrank
1200/1205 Overspeed
1300 Low Oil Pressure
1501/1505/1511/1515 RPM Sense Loss
1600 Underspeed

Each error code has its own set of causes and solutions. For example, if your generator displays an overcrank code, it means the engine attempted to start but failed after several tries. This could be due to issues such as a fuel supply problem or a faulty spark plug.

For a complete list of error codes and detailed troubleshooting steps, refer to our comprehensive generac generator error codes resource. If you find that your generac generator won’t reset or if you’re having trouble with the generac generator reset button, you might need to delve deeper into generac generator troubleshooting.

It’s essential to address these error codes promptly to prevent further damage to your generator. In some cases, you may be able to resolve the issue yourself by following the generac generator troubleshooting guide. However, if the problem persists or you’re unsure how to proceed, it’s best to contact a certified service dealer for assistance.

Understanding the basics of your Generac generator and the meaning behind common error codes empowers you to take the necessary steps to ensure your backup power source is always in optimal working condition. Whether you’re dealing with a generator that won’t start or you’re troubleshooting a battery issue (generac generator troubleshooting battery), the right knowledge and approach can help you quickly get your power back under control.

Troubleshooting Generac Generators

Experiencing issues with your Generac generator can be frustrating, but with some basic troubleshooting steps, you may be able to resolve the problem quickly. If your Generac generator keeps tripping, follow these guidelines to diagnose and potentially fix the issue.

Resetting Your Generator

Resetting your Generac generator is often the first step in troubleshooting. It can clear error codes and allow the system to restart and recalibrate. Here’s how you can reset your generator:

  1. Locate the reset button on the control panel.
  2. Press and hold the reset button for 10 seconds.
  3. Release the button and wait for the generator to power off.
  4. After a few minutes, restart the generator.

For detailed steps, visit our how to reset generac generator page. If the generator won’t reset, there may be a deeper issue that requires professional attention.

Diagnostic Steps

After attempting a reset, if the generator continues to display error codes or refuses to start, you’ll need to perform further diagnostics:

  1. Check the fuel supply to ensure it’s not interrupted or blocked.
  2. Examine the battery condition and connections. Refer to the generac generator troubleshooting battery guide for assistance.
  3. Review the oil level and quality. Low or dirty oil can lead to several issues, including the “Low Oil Pressure, Code 1300” error.
  4. Inspect the air filter for clogs or damage, as this can affect the generator’s operation.

For each error code, you can find specific troubleshooting tips in our generac generator error codes section.

Contacting Service Dealer

If the straightforward troubleshooting steps do not resolve the issue or if you encounter complex error codes like “Overcrank, Code 1100” or “Overspeed, Code 1200/1205,” it’s time to contact a service dealer. An authorized service dealer has the expertise to diagnose and repair more intricate problems that are beyond the scope of basic troubleshooting.

When reaching out to a service dealer:

  • Provide them with the specific error code and any other symptoms your generator is experiencing.
  • Describe any troubleshooting steps you have already taken.
  • Schedule a service call to have a professional technician inspect your generator.

For assistance finding a local authorized service dealer, visit our generac generator troubleshooting guide which includes contact information and further resources.

Remember, regular maintenance and prompt attention to any tripping issues will help ensure your Generac generator is ready when you need it most. If you’re struggling with your generator and it won’t start, don’t hesitate to seek professional help.

Specific Error Codes and Solutions

When your Generac generator experiences issues, it often communicates through error codes. Understanding what these codes mean can help you take the right action to resolve the problem. Below are some of the most common error codes and their corresponding solutions.

Overcrank, Code 1100

If your Generac generator displays an “Overcrank, Code 1100” error, it signifies that the generator tried to start unsuccessfully too many times. To resolve this, you should:

  1. Reset the controller using the generac generator reset instructions.
  2. Check the gas supply to ensure it’s adequate and flowing correctly.
  3. If the error persists after these steps, reach out to an authorized service dealer for assistance. (Generac FAQ)

Overspeed, Code 1200/1205

An “Overspeed, Code 1200/1205” error is an indicator of high RPM that could potentially harm your generator. This may be a sign of defective ignition coils, and thus:

  1. It is not recommended for you to attempt a resolution without proper knowledge.
  2. Contact an authorized service dealer for professional help with this issue. (Generac FAQ)

Low Oil Pressure, Code 1300

When faced with a “Low Oil Pressure, Code 1300” error, your generator is indicating that the oil pressure is too low, which could be due to a low oil level. To address this:

  1. Check the oil level in your generator and refill it following the guidelines in the owner’s manual.
  2. If refilling the oil doesn’t clear the error, a service call by a professional may be necessary. (Generac FAQ)

RPM Sense Loss, Code 1501/1505/1511/1515

Encountering an “RPM Sense Loss” error means the controller is not sensing the correct RPM. To attempt a fix:

  1. Clear the alarm from the controller.
  2. Remove some of the electrical loads and try restarting the generator.
  3. If these steps do not resolve the issue, the next course of action is to consult with a service dealer. (Generac FAQ)

Underspeed, Code 1600

The “Underspeed, Code 1600” error signifies that the controller is detecting an RPM that is lower than expected. For this error:

  1. A DIY fix is not recommended due to the complexity of the potential issues causing the error.
  2. Reach out to an authorized service dealer to diagnose and repair the problem. (Generac FAQ)
Error Code Problem Suggested Action
1100 Overcrank Reset controller, check gas, contact dealer
1200/1205 Overspeed Contact authorized service dealer
1300 Low Oil Pressure Check/refill oil, maybe service call
1501/1505/1511/1515 RPM Sense Loss Clear alarm, reduce loads, restart, or contact dealer
1600 Underspeed Contact authorized service dealer

Remember, if you’re ever unsure about how to proceed with an error code, it’s always best to consult the generac generator troubleshooting guide or reach out to a professional service dealer for guidance. Your safety and the proper functioning of your generator should always be a priority.

CONTACT US TODAY

    Pamela S.
    Pamela S.
    Google Review

    I thought Derek was polite. Courteous knew what he was doing. Got my furnace fixed in one day. I was very appreciative and because of his service I will now only use you guys going forward. He’s a great technician.

    Michael S.
    Michael S.
    Google Review

    I'm always impressed when a service provider takes the time to educate me about the product I bought. Eddie explained the protocols for maintaining my mini-splits
    , provided me with the knowledge that he brought to the inspection and showed me how to improve the longevity of the product. In the process he convinced me to extend my service.
    Good job -

    Joan C.
    Joan C.
    Google Review

    Eric, our Sanford tech, did wonderful as always. maintaining our beast of a heating system takes skill. He is prompt and kind gets the maintenance taken care of quickly. He doesn’t mind the annoying dogs or the beam that you have to duck under going up and down stairs.

    They check in the day before coming and Eric texts when on the way. He is always on time. We have been very happy with the work and the professionalism.

    Joyce
    Joyce
    Google Review

    This was my first time using Sanford. Derek was amazing. He diagnosed the problem quickly, showed me the problem, and then quoted me a price which was very reasonable. He had the part on the truck and had the problem fixed within a half hour. From the person I made the appointment with, Irish, to the dispatcher I spoke with for an estimated time of arrival, to Derek, my experience was nothing but positive. I had such a great experience that I will always use Sanford for my heating, cooling, and plumbing needs. Highly recommended!

    John M.
    John M.
    Google Review

    After Sanford did such an impressive job installing our new Bosch furnace last winter, it was a no brainer as to who we wanted to add a central air conditioner to our house.
    They gave us two options and we chose to go with a heat pump. Jason and his team did an incredible job installing the system in just a single day. The quality of their workmanship is second to none and he couldn’t be a nicer person to work with.
    Another great job by Sanford !

    David B.
    David B.
    Google Review

    We had Brian B come to our home to conduct a follow up visit to evaluate our Carrier AC that was installed in February. Just like the three-man crew who did the installation, Brian B did an outstanding job of making sure that everything was working just fine. He answered all our questions and made sure we were confident that our AC would be working fine this summer. Great job.

    Cathleen P.
    Cathleen P.
    Google Review

    Extremely happy with the service I received. Mike did an excellent job of servicing my HVAC system. He was very efficient, knowledgeable and took the time to answer all my questions. Also, the office personnel were very helpful and responsive to all my requests and questions regarding scheduling and pricing. I will be using them again and would highly recommend Mike.

    Janet L.
    Janet L.
    Google Review

    Excellent service. Arrived on time. Asked me questions to diagnose any possible issues. Explained several things I did not know about my system.

    Eric was very pleasant & thoroughly cleaned & diagnosed my system. Every Sanford employee with whom I have had dealings has been pleasant, attentive, and professional. A friend recommended Sanford to me & I recommend them to you as well. I have been very happy with my equipment & service & know I can contact them anytime with questions & concerns & they will respond in a timely manner. Thank you Eric!

    C P.
    C P.
    Google Review

    Our tech was great! He was respectful of the space (and rolled with the chaos of small kiddos running around like goons), knowledgeable, and efficient. We’ve used Sanford for years and will continue to do so.

    Kay H.
    Kay H.
    Google Review

    Kyle G. from Sanford was awesome and super respectful. They installed furnace and AC system. He explained everything without being condescending, helped set up the wireless system, checked it and his team cleaned up everything after the job. My standards are pretty high and Kyle not only met them, he exceeded them. Thank you.

    As Seen & Heard On

    Reach Out to Our Team for More Details

    Feel free to call Sanford Temperature Control or fill out the online form for more information. You may also get in touch with our team to schedule an appointment. We look forward to hearing from you.